                            Product offer and datasheets
                            PRODUCT NAME
                            USED FOR
                            DIMENSIONS
                            STANDARDS
                            DATA SHEET
                            PRODUCT NAME
                            Strenx® 100
                            USED FOR

                            Structural

                            DIMENSIONS

                            T: -4 - 5 Inches

                            STANDARDS

                            EN 10029

                            DATA SHEET

                            English

                            PRODUCT NAME
                            Strenx 100 XF
                            USED FOR

                            Structural

                            DIMENSIONS

                            T: 2 - 10 mm

                            W: Up to 1600 mm

                            L: Up to 16000 mm

                            STANDARDS

                            EN 10051

                            EN 10163-2 Class A, Subclass 3

                            DATA SHEET

                            English

                            PRODUCT NAME
                            Strenx 110 XF
                            USED FOR

                            Structural

                            DIMENSIONS

                            T: 2 - 10 mm

                            W: Up to 1600 mm

                            L: Up to 16000 mm

                            STANDARDS

                            EN 10051

                            EN 10163-2 Class A, Subclass 3

                            DATA SHEET

                            English

                            PRODUCT NAME
                            Strenx® 600MC D/E
                            USED FOR

                            Structural

                            DIMENSIONS

                            T: 2 - 10 mm

                            W: Up to 1600 mm

                            L: Up to 16000 mm

                            STANDARDS

                            EN 10149-2

                            EN 10051

                            EN 10163-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® 650MC D/E
                            USED FOR

                            Structural

                            DIMENSIONS

                            T: 2 - 10 mm

                            W: Up to 1600 mm

                            L: Up to 16000 mm

                            STANDARDS

                            EN 10149-2

                            EN 10051

                            EN 10163-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® 700 E/F
                            USED FOR

                            Structural

                            Low temperatures (down to -60°)

                            DIMENSIONS

                            T: 4 - 160 mm

                            W: Up to 3350 mm

                            L: Up to 14630 mm

                            STANDARDS

                            EN 10025-6

                            EN 10029

                            EN 10163-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® 700MC D/E
                            USED FOR

                            Structural

                            DIMENSIONS

                            T: 2 - 10 mm

                            W: Up to 1600 mm

                            L: Up to 16000 mm

                            STANDARDS

                            EN 10051

                            EN 10163-2

                            EN 10149-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® 700MC Plus
                            USED FOR

                            Structural

                            Low temperatures (down to -60°)

                            DIMENSIONS

                            T: 3 - 12 mm

                            W: Up to 1525 mm

                            L: Up to 12300 mm

                            STANDARDS

                            EN 10051

                            EN 10163-2

                            EN 10149-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® 700 CR
                            USED FOR

                            Structural

                            DIMENSIONS

                            T: 0.7 - 2.1 mm

                            W: Up to 1500 mm

                            L: Up to 8500 mm

                            STANDARDS

                            EN 10131

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® 700 OME
                            USED FOR

                            Structural

                            Low temperatures (down to -60°)

                            DIMENSIONS

                            T: 4 - 130 mm

                            W: Up to 3350 mm

                            L: Up to 14630 mm

                            STANDARDS

                            EN 10025-6

                            EN 10029

                            EN 10163-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® 900 E/F
                            USED FOR

                            Structural

                            Low temperatures (down to -60°)

                            DIMENSIONS

                            T: 4 - 100 mm

                            W: Up to 3350 mm

                            L: Up to 14630 mm

                            STANDARDS

                            EN 10025-6

                            EN 10029

                            EN 10163-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® 900MC
                            USED FOR

                            Structural

                            DIMENSIONS

                            T: 3 - 10 mm

                            W: Up to 1600 mm

                            L: Up to 13000 mm

                            STANDARDS

                            EN 10051

                            EN 10149-2

                            EN 10163-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® 900 Plus
                            USED FOR

                            Structural

                            DIMENSIONS

                            T: 2 - 8 mm

                            W: Up to 1600 mm

                            L: Up to 16000 mm

                            STANDARDS

                            EN 10025-6

                            EN 10051

                            EN 10163-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® 960 E
                            USED FOR

                            Structural

                            DIMENSIONS

                            T: 4 - 100 mm

                            W: Up to 3350 mm

                            L: Up to 14630 mm

                            STANDARDS

                            EN 10025-6

                            EN 10029

                            EN 10163-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® 960MC
                            USED FOR

                            Structural

                            DIMENSIONS

                            T: 3 - 10 mm

                            W: Up to 1600 mm

                            L: Up to 13000 mm

                            STANDARDS

                            EN 10051

                            EN 10163-2

                            EN 10149-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® 960 Plus
                            USED FOR

                            Structural

                            DIMENSIONS

                            T: 2 - 8 mm

                            W: Up to 1600 mm

                            L: Up to 16000 mm

                            STANDARDS

                            EN 10025-6

                            EN 10051

                            EN 10163-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® 960 CR
                            USED FOR

                            Structural

                            DIMENSIONS

                            T: 0.7 - 2.1 mm

                            W: Up to 1500 mm

                            L: Up to 8500 mm

                            STANDARDS

                            EN 10131

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® 1100 E/F
                            USED FOR

                            Structural

                            Low temperatures (down to -60°)

                            DIMENSIONS

                            T: 4 - 40 mm

                            W: Up to 3200 mm

                            L: Up to 14630 mm

                            STANDARDS

                            EN 10029

                            EN 10163-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® 1100 Plus
                            USED FOR

                            Structural

                            DIMENSIONS

                            T: 4 - 8 mm

                            W: Up to 1600 mm

                            L: Up to 16000 mm

                            STANDARDS

                            EN 10051

                            EN 10163-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® 1100MC
                            USED FOR

                            Structural

                            DIMENSIONS

                            T: 3 - 8 mm

                            W: Up to 1700 mm

                            L: Up to 16000 mm

                            STANDARDS

                            EN 10051

                            EN 10163-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® 1100 CR
                            USED FOR

                            Structural

                            DIMENSIONS

                            T: 0.7 - 2.1 mm

                            W: Up to 1500 mm

                            L: Up to 8500 mm

                            STANDARDS

                            EN 10131

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® 1300 E/F
                            USED FOR

                            Structural

                            Low temperatures (down to -60°)

                            DIMENSIONS

                            T: 4 - 15 mm

                            W: Up to 2900 mm

                            L: Up to 14630 mm

                            STANDARDS

                            EN 10029

                            EN 10163-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® Tube 700MH
                            USED FOR
                            DIMENSIONS

                            T: 3 - 10 mm

                            D: 33.7 - 323.9 mm

                            W: Up to 300 mm

                            L: Up to 18000 mm

                            STANDARDS

                            EN 10219-2

                            EN 1090-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® Tube 700MLH
                            USED FOR
                            DIMENSIONS

                            T: 3 - 10 mm

                            D: 33.7 - 323.9 mm

                            W: Up to 300 mm

                            L: Up to 18000 mm

                            STANDARDS

                            EN 10219-2

                            EN 1090-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® Tube 700QLH
                            USED FOR
                            DIMENSIONS

                            T: 2 - 6.3 mm

                            D: 25 - 133 mm

                            L: Up to 12000 mm

                            STANDARDS

                            EN 10210-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® Tube 900MH
                            USED FOR
                            DIMENSIONS

                            T: 4 - 6 mm

                            D: 114.3 - 244.5 mm

                            W: Up to 160 mm

                            L: Up to 18000 mm

                            STANDARDS

                            EN 10219-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® Tube 960MH
                            USED FOR
                            DIMENSIONS

                            T: 4 - 6 mm

                            D: 76.1 - 219.1 mm

                            W: Up to 160 mm

                            L: Up to 18000 mm

                            STANDARDS

                            EN 10219-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® Section 650
                            USED FOR
                            DIMENSIONS

                            T: 2.5 - 10 mm

                            L: Up to 21000 mm

                            STANDARDS

                            EN 10149-2

                            EN 10162

                            EN 1090-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® Section 700
                            USED FOR
                            DIMENSIONS

                            T: 2.5 - 10 mm

                            L: Up to 21000 mm

                            STANDARDS

                            EN 10149-2

                            EN 10162

                            EN 1090-2

                            DATA SHEET
                            PRODUCT NAME
                            Strenx® Section 900
                            USED FOR
                            DIMENSIONS

                            T: 3 - 6 mm

                            L: Up to 21000 mm

                            STANDARDS

                            EN 10149-2

                            EN 10162

                            DATA SHEET